Darkgrey aluminium cast with 4-leaf barndoor, Class A DMX512 for DMX512 controll, intern
Converts 0-10V Osram ballast.
Osram Studioline 3200K 55W - 5600K 55W
or Kino Flo - Philips.....
Studio 552DMX for 2x 55W 3200K 605x240x150mm 5,7Kg - 1 dmx adress
Studio 554DMX for 4x 55W 3200K 605x365x150mm 7,9Kg - 2 dmx adresses
Studio 556DMX for 6x 55W 3200K 450x645x150mm 10,5Kg - 3 dmx adresses
Ideal for lighting applications for medium and small sized studios, conference halls, field lighting as well as news studios.
|
| |
 |
|
General description
TL-rgb-V3 is designed to control 4 (groups) dimmable fluorescent ballasts, whose dim function operate on adjustable control voltage of 1 till 10 [V].
With this module it is possible to use DMX512 to switch the mains power as well as to provide the control voltage of 1-10 [V] for the ballast.
The mains voltage switch and de control voltage are controlled by the same DMX channel. The switching point is on 3% of the maximum DMX value.
The maximum load for each group is 200[VA]. The mains power switch becomes active at mains voltage zero crossing.
This way inrush currents are kept as low as possible. You can also set the lights to burn on any level without using DMX. This manual level setting has to be done for each channel separately and is stored in a non-volatile memory.
Setting the DMX address
You can change it as follows: first select a digit by pressing button [SELECT DIGIT]. A flashing decimal dot indicates the selected digit. Now you can change the value of the selected digit with the buttons [<<] or [>>].
Repeat this for all the digits you want to change. Changes are stored automatically. As soon as the new address has been stored in a non volatile memory the flashing decimal dot goes off.
At the moment you are changing the address the ballast fades to
zero in 6 [s].
After an address changing has been stored, the new setting fades in, in 6[s].
The DMX start address is displayed if:
1. the setting for 'hold DMX data (on loss of signal)' is Y(es) (default setting)
2. the setting for 'hold DMX data (on loss of signal)' is N(o) AND a DMX signal is present.
Switching points and control curves
The mains power switches on at 3% of the maximum DMX signal and switches off at 1%. You can set the relationship
between the DMX input signal and the analogue control voltage under setup. These relations are: linear (C1), linear
with 'offset' (C2) en non-linear with 'offset' (C3).
· C1 Linear: if DMX-in = 0,.......,100% than V-control out = 0,.......,10[V].
· C2 Linear with offset: if DMX-in = 0,..,3% than V-control out = 0[V],
if DMX-in >3%,.......,100% than V-control = 0,8[V],.....,10[V].
· C3 Non-linear with offset: the same as above, except the increase of intensity per percent in the beginning of the
control curve is smaller than at the end of the curve.
See under set up how to set these curves.
Set up
Holding the DMX data or not on loss of DMX-signal
Keep pressed button [SELECT DIGIT] for 8 seconds. The display shows: H=Y or H=N. The third dot is flashing.
With the buttons [<<] or [>>] you can change from Y to N and visa versa
Pricelist: DSTTL Studiolight Fluorescent DMX - non DMX |